Ted Clancy
Ted Clancy
Verified email at wpi.edu
Title
Cited by
Cited by
Year
Electrical alternans and cardiac electrical instability.
JM Smith, EA Clancy, CR Valeri, JN Ruskin, RJ Cohen
Circulation 77 (1), 110-121, 1988
6621988
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
EA Clancy, EL Morin, R Merletti
Journal of electromyography and kinesiology 12 (1), 1-16, 2002
6222002
Length of disability and cost of workers' compensation low back pain claims
L Hashemi, BS Webster, EA Clancy, E Volinn
Journal of occupational and environmental medicine 39 (10), 937-945, 1997
2571997
Trends in disability duration and cost of workers' compensation low back pain claims (1988-1996)
L Hashemi, BS Webster, EA Clancy
Journal of Occupational and Environmental Medicine 40 (12), 1110-1119, 1998
1841998
Probability density of the surface electromyogram and its relation to amplitude detectors
EA Clancy, N Hogan
IEEE Transactions on Biomedical Engineering 46 (6), 730-739, 1999
1531999
Length of disability and cost of work-related musculoskeletal disorders of the upper extremity
L Hashemi, BS Webster, EA Clancy, TK Courtney
Journal of Occupational and Environmental Medicine 40 (3), 261-269, 1998
1361998
Relating agonist-antagonist electromyograms to joint torque during isometric, quasi-isotonic, nonfatiguing contractions
EA Clancy, N Hogan
IEEE Transactions on Biomedical Engineering 44 (10), 1024-1028, 1997
1081997
Estimation and application of EMG amplitude during dynamic contractions
EA Clancy, S Bouchard, D Rancourt
IEEE Engineering in Medicine and Biology Magazine 20 (6), 47-54, 2001
992001
Multiple site electromyograph amplitude estimation
EA Clancy, N Hogan
IEEE Transactions on Biomedical Engineering 42 (2), 203-211, 1995
961995
Single site electromyograph amplitude estimation
EA Clancy, N Hogan
IEEE transactions on biomedical engineering 41 (2), 159-167, 1994
951994
Adaptive whitening of the electromyogram to improve amplitude estimation
EA Clancy, KA Farry
IEEE transactions on Biomedical Engineering 47 (6), 709-719, 2000
882000
A descriptive study of recurrent low back pain claims
MJ MacDonald, GS Sorock, E Volinn, L Hashemi, EA Clancy, B Webster
Journal of occupational and environmental medicine 39 (1), 35-43, 1997
821997
A soft robotic exomusculature glove with integrated sEMG sensing for hand rehabilitation
MA Delph, SA Fischer, PW Gauthier, CHM Luna, EA Clancy, GS Fischer
2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR), 1-7, 2013
812013
Influence of advanced electromyogram (EMG) amplitude processors on EMG-to-torque estimation during constant-posture, force-varying contractions
EA Clancy, O Bida, D Rancourt
Journal of biomechanics 39 (14), 2690-2698, 2006
782006
Identification of constant-posture EMG–torque relationship about the elbow using nonlinear dynamic models
EA Clancy, L Liu, P Liu, DVZ Moyer
IEEE Transactions on Biomedical Engineering 59 (1), 205-212, 2011
702011
Multi-channel electrophysiologic signal data acquisition system on an integrated circuit
EA Clancy, JA Mcneill, WR Michalson
US Patent 7,896,807, 2011
682011
Meteorological conditions and self-report of low back pain
RW McGorry, SM Hsiang, SH Snook, EA Clancy, SL Young
Spine 23 (19), 2096-2102, 1998
581998
Influence of smoothing window length on electromyogram amplitude estimates
Y St-Amant, D Rancourt, EA Clancy
IEEE transactions on Biomedical Engineering 45 (6), 795-799, 1998
571998
Electromyogram whitening for improved classification accuracy in upper limb prosthesis control
L Liu, P Liu, EA Clancy, E Scheme, KB Englehart
IEEE Transactions on Neural Systems and Rehabilitation Engineering 21 (5 …, 2013
562013
Electromyogram amplitude estimation with adaptive smoothing window length
EA Clancy
IEEE Transactions on Biomedical Engineering 46 (6), 717-729, 1999
551999
The system can't perform the operation now. Try again later.
Articles 1–20