Abouzeid A. Thabet
Abouzeid A. Thabet
PhD., Lecturer at PUA
Verified email at pua.edu.eg - Homepage
Title
Cited by
Cited by
Year
Fabrication, characterization and gamma rays shielding properties of nano and micro lead oxide-dispersed-high density polyethylene composites
ME Mahmoud, AM El-Khatib, MS Badawi, AR Rashad, RM El-Sharkawy, ...
Radiation Physics and Chemistry 145, 160-173, 2018
542018
Recycled high-density polyethylene plastics added with lead oxide nanoparticles as sustainable radiation shielding materials
ME Mahmoud, AM El-Khatib, MS Badawi, AR Rashad, RM El-Sharkawy, ...
Journal of Cleaner Production 176, 276-287, 2018
412018
An empirical formula to calculate the full energy peak efficiency of scintillation detectors
MS Badawi, M Abd-Elzaher, AA Thabet, AM El-khatib
Applied Radiation and Isotopes 74, 46-49, 2013
282013
Determination of full energy peak efficiency of NaI (Tl) detector depending on efficiency transfer principle for conversion form experimental values
M Abd-Elzaher, MS Badawi, A El-Khatib, AA Thabet
Scientific Research Publishing, 2012
212012
Full-Energy peak efficiency of an NaI (Tl) detector with coincidence summing correction showing the effect of the source-to-detector distance
AM El-Khatib, BA Salem, MS Badawi, MM Gouda, AA Thabet, MI Abbas
Chinese journal of Physics 55 (2), 478-489, 2017
182017
A numerical approach to calculate the full-energy peak efficiency of HPGe well-type detectors using the effective solid angle ratio
MS Badawi, I Ruskov, MM Gouda, AM El-Khatib, MF Alotiby, ...
Journal of Instrumentation 9 (07), P07030, 2014
172014
Calibration of а single hexagonal NaI (Tl) detector using a new numerical method based on the efficiency transfer method
MI Abbas, MS Badawi, IN Ruskov, AM El-Khatib, DN Grozdanov, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2015
152015
Calibration of well-type NaI (Tl) detector using a point sources measured out the detector well at different axial distances
MM Gouda, MS Badawi, AM El-Khatib, MM Mohamed, AA Thabet, ...
Journal of Instrumentation 10 (03), P03022, 2015
142015
Study on the effect of the self-attenuation coefficient on γ-ray detector efficiency calculated at low and high energy regions
AM El-Khatib, AA Thabet, MA Elzaher, MS Badawi, BA Salem
Nuclear Engineering and Technology 46 (2), 217-224, 2014
132014
Experimental verification of gamma-efficiency calculations for scintillation detectors in angle 4 software
AA Thabet, AD Dlabac, SI Jovanovic, MS Badawi, NN Mihaljevic, ...
Nuclear Technology and Radiation Protection 30 (1), 35-46, 2015
122015
Calculation of the Peak Efficiency for NaI (Tl) Gamma Ray Detector Using the Effective Solid Angle Method
A El-Khatib, MS Badawi, M Abd-Elzaher, AA Thabet
Journal of Advanced Research in Physics 3 (2), 2012
112012
Mathematical method to calculate full-energy peak efficiency of detectors based on transfer technique
MM Gouda, A Hamzawy, MS Badawi, AM El-Khatib, AA Thabet, MI Abbas
Indian Journal of Physics 90 (2), 201-210, 2016
92016
Well-type NaI (Tl) detector efficiency using analytical technique and ANGLE 4 software based on radioactive point sources located out the well cavity
AM El-Khatib, MS Badawi, AA Thabet, SI Jovanovic, MM Gouda, ...
Chinese Journal of Physics 54 (3), 338-346, 2016
82016
Study of some γ-ray attenuation parameters for new shielding materials composed of nano ZnO blended with high density polyethylene
Z Alsayed, MS Badawi, R Awad, AA Thabet, AM El-Khatib
Nuclear Technology and Radiation Protection 34 (4), 342-352, 2019
52019
Calibration of 4π NaI (Tl) detectors with coincidence summing correction using new numerical procedure and ANGLE4 software
MS Badawi, SI Jovanovic, AA Thabet, AM El-Khatib, AD Dlabac, ...
AIP Advances 7 (3), 035005, 2017
52017
World J
MA Elzaher, MS Badawi, AM El-Khatib, AA Thabet
Nucl. Sci. Technol 2, 65-72, 2012
52012
New analytical approach to calculate the full energy peak efficiency for NaI (Tl) gamma-ray detector using the effective solid angle method
AM El-Khatib, MS Badawi, MA Elzaher, AA Thabet
International Journal of Instrumentation Science 1 (3), 25-33, 2012
52012
Efficiency of a cubic NaI (Tl) detector with rectangular cavity using standard radioactive point sources placed at non-axial position
MI Abbas, MS Badawi, AA Thabet, YN Kopatch, IN Ruskov, ...
Applied Radiation and Isotopes 163, 109139, 2020
42020
New numerical simulation method to calibrate the regular hexagonal NaI (Tl) detector with radioactive point sources situated non-axial
A Hamzawy, DN Grozdanov, MS Badawi, FA Aliyev, AA Thabet, MI Abbas, ...
Review of Scientific Instruments 87 (11), 115105, 2016
42016
Ex per i men tal Ver i fi ca tion of Gamma-Ef fi ciency Cal cu la tions For Scin til la tion De tec tors in An gle 4 Soft ware
A Thabet
Nucl Technol Radiat 30 (1), 2015
42015
The system can't perform the operation now. Try again later.
Articles 1–20