Ni Ketut Aryani
Ni Ketut Aryani
Department of Electrical Engineering, Institut Teknologi Sepuluh Nopember
Verified email at elect-eng.its.ac.id
Title
Cited by
Cited by
Year
Optimal placement and sizing of distributed generation for minimize losses in unbalance radial distribution systems using quantum genetic algorithm
NK Aryani, M Syai'in, A Soeprijanto, IMY Negara
International Review of Electrical Engineering (IREE) 9 (1), 157-164, 2014
242014
Dynamic economic dispatch of hybrid microgrid with energy storage using quadratic programming
RS Wibowo, KR Firmansyah, NK Aryani, A Soeprijanto
2016 IEEE Region 10 Conference (TENCON), 667-670, 2016
182016
Optimal placement and sizing of Distributed Generation using Quantum Genetic Algorithm for reducing losses and improving voltage profile
NK Aryani, M Abdillah, IMY Negara, A Soeprijanto
TENCON 2011-2011 IEEE Region 10 Conference, 108-112, 2011
102011
Analysis of physical and electrical characteristics of transformer oil insulation during accelerated thermal aging experiment and its lifetime estimation using arrhenius law …
IMY Negara, NK Aryani, DA Asfani, D Fahmi, R Jauhari, M Wahyudi
2017 International Seminar on Intelligent Technology and Its Applications …, 2017
52017
Manajemen Gangguan Jaringan Distribusi 20 kV Kota Surabaya berbasis Geographic Information System (GIS) menggunakan Metode Algoritma Genetika
C Rochman, O Penangsang, NK Aryani
Jurnal Teknik ITS 6 (1), B51-B56, 2017
52017
Studi Perbaikan Stabilitas Tegangan Sistem Jawa-Madura-Bali (Jamali) dengan Pemasangan SVC Setelah Masuknya Pembangkit 1000 MW Paiton
HP Prayitno, O Penangsang, NK Aryani
Jurnal Teknik ITS 5 (2), B244-B250, 2016
52016
Unit commitment with non-smooth generation cost function using binary particle swarm optimization
RS Wibowo, FF Utama, DFU Putra, NK Aryani
2016 International Seminar on Intelligent Technology and Its Applications …, 2016
52016
Economic dispatch using quantum evolutionary algorithm in electrical power system involving distributed generators
NK Aryani, A Soeprijanto, IMY Negara, M Syai’in
International Journal of Electrical and Computer Engineering 7 (5), 2365, 2017
42017
Life-cycle cost analysis of laboratory scale micro-grid operation in power system simulation laboratory using HOMER simulation
JJ Gandhi, O Penangsang, A Soeprijanto, NK Aryani
2016 International Seminar on Intelligent Technology and Its Applications …, 2016
42016
Dynamic OPF considering different charging and discharging cost of energy storage using mixed-integer quadratic programming
RS Wibowo, FY Purnomo, NK Aryani, O Penangsang
2017 International Seminar on Intelligent Technology and Its Applications …, 2017
32017
Penentuan Lokasi Gangguan Hubung Singkat pada Jaringan Distribusi 20 kV Penyulang Tegalsari Surabaya dengan Metode Impedansi Berbasis GIS (Geographic Information System)
O Penangsang, NK Aryani
Jurnal Teknik ITS 6 (1), B66-B71, 2017
32017
Security constrained dynamic optimal power flow with multiple energy storage
RS Wibowo, YB Nugraha, DA Asfani, O Penangsang, NK Aryani
TENCON 2017-2017 IEEE Region 10 Conference, 1885-1889, 2017
22017
Security Constrained Unit Commitment with Non-smooth Generation Cost Function Using Binary Particle Swarm Optimization Algorithm
AS Daroini, NK Aryani, RS Wibowo, EA Arifin
2019 International Seminar on Intelligent Technology and Its Applications …, 2019
12019
Optimizing Tie Switches Allocation and Sizing Distributed Generation (DG) Based on Maximize Loadability Simultaneously Using HPSO Algorithm
DA Wicaksono, O Penangsang, RS Wibowo, NK Aryani, DFU Putra
2019 International Seminar on Intelligent Technology and Its Applications …, 2019
12019
Distributed generation (DG) placement for reducing power losses on radial distribution system using k-means clustering method
O Penangsang, MA Amanullah, NK Aryani
ARPN Journal of Engineering and Applied Sciences 13 (5), 1570-1577, 2018
12018
Optimasi Aliran Daya Satu Phasa Pada Sistem Distribusi Radial 33 Bus IEEE dan Sistem Kelistrikan PT. Semen Indonesia Aceh Untuk Meminimasi Kerugian Daya dan Deviasi Tegangan …
AE Prihadana, O Penangsang, NK Aryani
Jurnal Teknik ITS 5 (2), B207-B216, 2016
12016
Analisa Stabilitas Transien Pada Sistem Transmisi Sumatera Utara 150 kV-275 kV dengan Penambahan PLTA Batang Toru 4 x 125 MW
DT Kumara
Institut Teknologi Sepuluh Nopember, 2016
12016
Optimal Placement and Sizing Distributed Generation (DG) Considering Energy Storage Using ABC-QP Algorithm
L Fajariyanti, RS Wibowo, O Penangsang, DFU Putra, NK Aryani
2019 International Seminar on Intelligent Technology and Its Applications …, 2019
2019
Security Constrained Unit Commitment Considering Ramp Rate and Transmission Line Losses Using Binary Particle Swarm Optimization Based on IEEE 30 Bus System
NK Aryani, DFU Putra, EA Arifin, AS Daroini
2019 International Seminar on Intelligent Technology and Its Applications …, 2019
2019
Power Swing Phenomenon on Jawa Bali 500 kV and Its Mitigation
RM Azmi, O Penangsang, NK Aryani, G Manuella
2019 International Seminar on Intelligent Technology and Its Applications …, 2019
2019
The system can't perform the operation now. Try again later.
Articles 1–20