Real-time viscosity and mass density sensors requiring microliter sample volume based on nanomechanical resonators BA Bircher, L Duempelmann, K Renggli, HP Lang, C Gerber, N Bruns, ... Analytical chemistry 85 (18), 8676-8683, 2013 | 64 | 2013 |
Single-cell lysis for visual analysis by electron microscopy S Kemmerling, SA Arnold, BA Bircher, N Sauter, C Escobedo, G Dernick, ... Journal of structural biology 183 (3), 467-473, 2013 | 38 | 2013 |
Automated high-throughput viscosity and density sensor using nanomechanical resonators BA Bircher, R Krenger, T Braun Sensors and Actuators B: Chemical 223, 784-790, 2016 | 34 | 2016 |
Disentangling mechanical and mass effects on nanomechanical resonators RR Grüter, Z Khan, R Paxman, JW Ndieyira, B Dueck, BA Bircher, ... Applied physics letters 96 (2), 023113, 2010 | 34 | 2010 |
Predicting laser powder bed fusion defects through in-process monitoring data and machine learning S Feng, Z Chen, B Bircher, Z Ji, L Nyborg, S Bigot Materials & Design 222, 111115, 2022 | 31 | 2022 |
Photothermal excitation of microcantilevers in liquid: effect of the excitation laser position on temperature and vibrational amplitude BA Bircher, L Duempelmann, HP Lang, C Gerber, T Braun Micro & Nano Letters, 2013 | 31 | 2013 |
X-ray flat-panel detector geometry correction to improve dimensional computed tomography measurements M Lüthi, BA Bircher, F Meli, A Küng, R Thalmann Measurement Science and Technology 31 (3), 035002, 2020 | 24 | 2020 |
CT geometry determination using individual radiographs of calibrated multi-sphere standards BA Bircher, F Meli, A Küng, R Thalmann iCT 2019, 2019 | 18 | 2019 |
A geometry measurement system for a dimensional cone-beam CT BA Bircher, F Meli, A Küng, R Thalmann 8th Conference on Industrial Computed Tomography (iCT 2018), 2018 | 18 | 2018 |
METAS-CT: Metrological X-ray computed tomography at sub-micrometre precision BA Bircher, F Meli, A Küng, R Thalmann euspen’s 20th International Conference & Exhibition, Geneva, CH, June 2020, 2020 | 11* | 2020 |
Characterising the positioning system of a dimensional computed tomograph (CT) BA Bircher, F Meli, A Küng, R Thalmann Proc. MacroScale—Recent Developments in Traceable Dimensional Measurements …, 2018 | 11 | 2018 |
Influence of squeeze-film damping on higher-mode microcantilever vibrations in liquid BA Bircher, R Krenger, T Braun EPJ Techniques and Instrumentation 1 (1), 10, 2014 | 11 | 2014 |
X-ray source tracking to compensate focal spot drifts for dimensional CT measurements BA Bircher, F Meli, A Küng, R Thalmann 10th Conference on Industrial Computed Tomography, 2020 | 9 | 2020 |
Measurement of temperature induced X-ray tube transmission target displacements for dimensional computed tomography BA Bircher, S Neuhaus, A Küng, F Meli Precision Engineering, 2021 | 7 | 2021 |
Low-Cost 2D Index and Straightness Measurement System Based on a CMOS Image Sensor A Küng, BA Bircher, F Meli Sensors 19 (24), 5461, 2019 | 7 | 2019 |
Array based real-time measurement of fluid viscosity and mass densities to monitor biological filament formation P Oliva, BA Bircher, CA Schoenenberger, T Braun Lab on a Chip, 2019 | 7 | 2019 |
Traceable X-ray focal spot reconstruction by circular edge analysis: From sub-microfocus to mesofocus BA Bircher, F Meli, A Kueng, A Sofiienko Measurement Science and Technology, 2022 | 6 | 2022 |
Methodologies for model parameterization of virtual CTs for measurement uncertainty estimation F Binder, BA Bircher, R Laquai, A Kueng, C Bellon, F Meli, A Deresch, ... Measurement Science and Technology, 2022 | 5 | 2022 |
High-resolution X-ray computed tomography for additive manufacturing: Towards traceable porosity defect measurements using digital twins BA Bircher, S Wyss, D Gage, A Küng, C Körner, F Meli | 5 | 2021 |
A geometry measurement system for a dimensional cone-beam CT 8th Conference on Industrial Computed Tomography BA Bircher, F Meli, A Küng, R Thalmann Wels, Austria (iCT 2018), 2018 | 5 | 2018 |