The role of abdominal compliance, the neglected parameter in critically ill patients-a consensus review of 16. Part 2: measurement techniques and management recommendations. ML Malbrain, I De Laet, JJ De Waele, M Sugrue, A Schachtrupp, ... Anaesthesiology intensive therapy 46 (5), 406-432, 2014 | 89 | 2014 |
The role of abdominal compliance, the neglected parameter in critically ill patients-a consensus review of 16. Part 1: definitions and pathophysiology M Malbrain, DJ Roberts, I De Laet, JJ De Waele, M Sugrue, ... Anaesthesiology intensive therapy 46 (5), 392-405, 2014 | 86 | 2014 |
Direct measurement of intra-abdominal pressure with a solid microtranducer FF Pracca, AA Biestro, L Moraes, CB Puppo, SM Calvo, J Gorrasi, ... Journal of clinical monitoring and computing 21, 167-170, 2007 | 25 | 2007 |
Non-invasive negative pressure system to treat abdominal hypertension M David, F Pracca, F Simini 5th European Conference of the International Federation for Medical and …, 2012 | 15 | 2012 |
Negative pressure device for intra-abdominal pressure reduction M David, D Geido, F Pracca, G Sánchez, F Simini, C Zoppolo Journal of Physics: Conference Series 90 (1), 012035, 2007 | 15 | 2007 |
Towards a continuous non-invasive assessment of intra-abdominal pressure based on bioimpedance and microwave reflectometry: A pilot run on a porcine model M David, A Raviv, A Peretz, U Berkovich, F Pracca Biomedical Signal Processing and Control 44, 96-100, 2018 | 14 | 2018 |
Acute intestinal failure: International multicenter point-of-prevalence study AR Blaser, I Ploegmakers, M Benoit, M Holst, HH Rasmussen, R Burgos, ... Clinical nutrition 39 (1), 151-158, 2020 | 12 | 2020 |
ABDOPRE: an external device for the reduction of intra-abdominal pressure F Pracca, A Biestro, J Gorrassi, M David, F Simini, M Cancela Revista Brasileira de Terapia Intensiva 23, 238-241, 2011 | 12 | 2011 |
Non-invasive indirect monitoring of intra-abdominal pressure using microwave reflectometry: System design and proof-of-concept clinical trial M David, A Raviv, A Guttel, V García Reyes, F Simini, F Pracca Journal of Clinical Monitoring and Computing 35, 1437-1443, 2021 | 11 | 2021 |
Intra-abdominal hypertension and hypoxic respiratory failure together predict adverse outcome–A sub-analysis of a prospective cohort A Regli, AR Blaser, B De Keulenaer, J Starkopf, E Kimball, ... Journal of Critical Care 64, 165-172, 2021 | 10 | 2021 |
A numerical analysis towards the continuous non-invasive assessment of intra-abdominal pressure in critical patients based on bioimpedance and microwave reflectometry M David, U Berkovich, F Pracca 2017 IEEE Biomedical Circuits and Systems Conference (BioCAS), 1-4, 2017 | 9 | 2017 |
The role of abdominal compli‑ance, the neglected parameter in critically ill patients—a consensus review of 16. Part 2: measurement techniques and management recom‑mendations … ML Malbrain, I De Laet, JJ De Waele, M Sugrue, A Schachtrupp, ... Epub 2014/11/30. eng, 2014 | 7 | 2014 |
Non-invasive treatment of abdominal hypertension: a new vacuum chamber L Urruty, F Simini, M Pereyra, M David, F Pracca 36th Annual International Conference of the IEEE Engineering in Medicine and …, 2014 | 5* | 2014 |
ABDOPRE: dispositivo de aplicação externa para redução da pressão intra-abdominal: Experiencia clínica preliminar F Pracca, A Biestro, J Gorrassi, M David, F Simini, M Cancela Revista Brasileira de Terapia Intensiva 23, 238-241, 2011 | 5 | 2011 |
Treatment of abdominal hypertension: Development of an original non-invasive device ABDOPRE A Schandy, F Pracca, F Simini VIII Latin American Conference on Biomedical Engineering and XLII National …, 2020 | 3 | 2020 |
Effects of peep and bed recumbent angle on intraab-dominal pressure measurement F Pracca, J Gorrasi, L Moraes, A Iturralde, C Puppo, A Biestro, M Canceta Acta Clinica Belgica 62, 264-265, 2007 | 3 | 2007 |
Intra-abdominal pressure monitoring by Surface Bioimpedance Estimation M David, E Yellin, F Pracca, F Simini Journal of Physics: Conference Series 1272 (1), 012013, 2019 | 2 | 2019 |
Towards the detection of intraintestinal gas by microwave reflectometry in critical patients S Buchnik, M Gelgor, F Pracca, M David 2021 IEEE URUCON, 291-293, 2021 | 1 | 2021 |
Optimized electrical bioimpedance measurements of abdominal wall on a porcine model for the continuous non-invasive assessment of intra-abdominal pressure M David, O Amran, A Peretz, A Raviv, F Pracca Journal of Clinical Monitoring and Computing 34, 1209-1214, 2020 | 1 | 2020 |
Intra-abdominal hypertension assessment based on Near Infra-Red reflectometry: New model and low-cost device M David, N Halevi, E Hirshtal, A Peretz, A Raviv, F Pracca Measurement 154, 107456, 2020 | 1 | 2020 |