José Machado da Silva
José Machado da Silva
Associate Professor, Faculdade de Engenharia da Universidade do Porto
Verified email at gcloud.fe.up.pt - Homepage
Title
Cited by
Cited by
Year
Dynamic characterisation of analogue-to-digital converters
D Dallet, JM da Silva
Springer Science & Business Media, 2006
652006
Supply current test of analogue and mixed signal circuits
IM Bell, SJ Spinks, J Machado da Silva
IEE Proceedings - Circuits, Devices and Systems 143 (6), 399 - 407, 1996
451996
Design and Evaluation of Novel Textile Wearable Systems for the Surveillance of Vital Signals
IG Trindade, J Machado da Silva, R Miguel, M Pereira, J Lucas, L Oliveira, ...
Senors 16 (10), 2016
292016
Literature on wearable technology for connected health: Scoping review of research trends, advances, and barriers
T Loncar-Turukalo, E Zdravevski, JM da Silva, I Chouvarda, V Trajkovik
Journal of medical Internet research 21 (9), e14017, 2019
222019
Cross-correlation between iDD and vOUT signals for testing analogue circuits
JMH Da Silva, JS Matos, IM Bell, GE Taylor
Electronics Letters 31 (19), 1617-1618, 1995
181995
Characterization of the electrode-skin impedance of textile electrodes
CC Oliveira, JM da Silva, IG Trindade, F Martins
Design of Circuits and Integrated Systems, 1-6, 2014
162014
Mixed current/voltage observation towards effective testing of analog and mixed-signal circuits
JM Da Silva, JS Matos, IM Bell, GE Taylor
Journal of Electronic Testing 9 (1-2), 75-88, 1996
161996
Novel textile systems for the continuous monitoring of vital signals: design and characterization
IG Trindade, F Martins, R Dias, C Oliveira, JM da Silva
2015 37th annual international conference of the IEEE engineering in …, 2015
142015
A Wearable Sensor Network for Human Locomotion Data Capture.
A Zambrano, F Derogarian, R Dias, MJ Abreu, AP Catarino, AM Rocha, ...
pHealth, 216-223, 2012
142012
A pull-in based test mechanism for device diagnostic and process characterization
LA Rocha, L Mol, E Cretu, RF Wolffenbuttel, JM Da Silva
142008
Implantable flexible pressure measurement system based on inductive coupling
CC Oliveira, AT Sepúlveda, N Almeida, BL Wardle, JM da Silva, ...
IEEE Transactions on Biomedical Engineering 62 (2), 680-687, 2014
132014
A flexible wearable sensor network for bio-signals and human activity monitoring
R Dias, JM da Silva
2014 11th International Conference on Wearable and Implantable Body Sensor …, 2014
132014
Dynamic testing of A/D converters by means of the three-parameter sine-fit algorithm
D Belega, D Dallet
Measurement 40 (1), 1-7, 2007
132007
Low-power in-circuit testing of a LNA
JM da Silva
IMSTW, 2005
92005
DYNAD: a framework IV SMT project addressed to the development of dynamic test techniques for analog-to-digital converters
C Morandi, G Chiorboli, D Dallet, D Haddadi, S Mazzoleni, JM da Silva, ...
Computer Standards & Interfaces 22 (2), 113-119, 2000
92000
Evaluation of iDD/vOUT cross-correlation for mixed current-voltage testing of analogue and mixed-signal circuits
J Machado da Silva, JS Matos
Proceedings ED&TC European Design and Test Conference, 264 - 268, 1996
91996
A low-power oscillation based LNA BIST scheme
JM Da Silva
International Conference on Design and Test of Integrated Systems in …, 2006
82006
A stent-graft endoleakage monitor: Telemetry system based on inductive-coupling transmission for implantable pressure sensors
C Oliveira, N Almeida, JM da Silva
2013 IEEE 3rd Portuguese Meeting in Bioengineering (ENBENG), 1-4, 2013
72013
A true power detector for RF PA built-in calibration and testing
PF Da Mota, JM Da Silva
2011 Design, Automation & Test in Europe, 1-6, 2011
72011
Auto-calibrated capacitive MEMS accelerometer
LA Rocha, L Mol, E Cretu, RF Wolffenbuttel, JM da Silva
14th IEEE International Mixed-Signals, Sensors and Systems Test Workshop …, 2008
72008
The system can't perform the operation now. Try again later.
Articles 1–20